Sale!

Richmar THERADOT Deep Oscillation Therapy Device

Original price was: $4,215.95.Current price is: $210.38.

SKU: oiqhgpkq18363 Category:

Description

Instruction Manual: Click Here
Deep Oscillation Therapy is a unique therapeutic treatment for rehab that is FDA-cleared formuscle relaxation, increasing circulation, and pain relief, which are important factors in restoring function and maintaining muscle mobility. Deep oscillation therapy is felt as a gentle vibration within the tissues, which relaxes the underlying muscles, making soft tissues more pliable for manipulations aimed at increasing range of motion. The massaging effect created by the oscillations within the patient’s tissues work to open pathways and increase the flow of blood and lymph throughout the body. Once the flow of blood, oxygen, and nutrients is restored to muscles afflicted by adhesions from injury or microtrauma, the resulting pain is diminished, and mobility is increased.
TheRichmar THERADOTprovides the latest technology to improve patient outcomes in the worlds of Athletic Training, Chiropractic, Physical Therapy, and Continuing Care (Long Term Care), and continues to be a staple in the toolbelt of sports medicine specialists worldwide, including in College and the “Big 4” professional sports leagues. Thousands of athletes are able to work hard, play hard, and recover faster with the help of the THERADOT.
Product Features:

  • Multi-Color Display with a Simple-to-Use Interface
  • ONE Built-In Practice-Specific Protocol Card for Athletic Training, Rehab, Chiropractic, & Continuing Care Treatments
  • 31 Evidence-Based Programmed Treatment Protocols To Choose From
  • Option To Administer Deep Oscillation Using Hands Through Vinyl Gloves For The Clinician OR With The Included Self-Treatment Kit For Personal Use At Home
  • Easily Transportable, Lightweight, Handheld Design
  • Internal Rechargeable Battery
  • FDA-cleared
  • 3 Year Manufacturer Warranty

Indications For Use:

  • Muscle relaxation
  • Increase circulation
  • Assists with lymphatic drainage
  • Temporary relief of minor aches & pains
  • Edema reduction
  • Improvement of wound healing

Contraindications:
Patients with the following disease(s) or conditions MUST NOT use the THERADOT.

  • Acute infections;
  • Acute inflammations with participation of pathogenic agents;
  • Active tuberculosis;
  • Acute venous diseases (untreated thromboses);
  • Untreated malignant processes;
  • Erysipelas;
  • Patients & therapists with cardiac pacemakers & other electronic implants;
  • Untreated heart disorders & diseases, especially cardiac insufficiency, decompensated cardiac edema, & cardiac arrhythmia;
  • Pregnancy;
  • Hypersensitivity to electrostatic fields;
  • Infectious skin diseases;
  • Vertebrobasilar insufficiency (VBI).

Technical Specifications:

  • GENERAL
    • Device Dimensions (W×L×H): 3.01″ x 5.65″ x 1.4″ (76.5 x 143.5 x 35.5mm)
    • Device Weight: 0.5 lbs
    • Interface: 2.8″ LCD screen
    • Software Release Version: A
  • PERFORMANCE
    • Channels: Two
    • Output Waveform: Symmetrical biphasic pulse
    • Output Voltage: Adjustable, 0-900V (p-p), display 0-100%, stepping 10%.
    • Output Frequency: Adjustable, 5-300 Hz, stepping 1 Hz
    • Modulation (on/off ratio): 1/4, 1/3, 1/2, 2/3, 3/4, 1/1, 2/1, 3/1, 4/1
    • Output Impedance: 6 MO
    • Timer: Max. 90 mins, divided into up to three stages, each stage is 1-30 mins, default 20 mins, stepping 1 min.

Each Richmar THERADOT Package Includes Everything Needed To Begin Treatment Right Away:

  • THERADOT Device (Part #: DO1009)
  • THERADOT Device Stand (Part #: DO1009STND)
  • Wall Adapter & USB Power Cord (Part #: DO1009X)
  • 2x Sets of Pin Lead Wires for Electrodes (White) (Part #: DO1009PINLW)
  • 2x Sets of Applicator/Titanium Element Lead Wires (Grey) (Part #: DO1009APPLW)
  • 1x Self-Applicator Handle (Part #: DO1009APP)
  • 1x Titanium Neutral Element (Part #: DO1009ELEM)
  • 1x 5.5cm Diameter Self-Treatment Oscillating Head (Part #: DO1099APP5)
  • 1x 10cm Diameter Self-Treatment Oscillating Head (Part #: DO1009APP10)
  • Richmar MultiStim Electrodes, 2″ x 2″ Square, 4 Pads Per Pack (Part #: 400-8772)
  • 1x Box of Vinyl Gloves, 100 Gloves per Box (Part #: VGPF3003)
  • Zipper Carrying Case (Part #: DO1009BAG)
  • Instruction Manual

*Please contact us if any replacement accessories are ever needed

Clinical Resources

The Richmar THERADOT device is an advanced therapeutic tool designed to aid in the treatment of various conditions, including muscle pain, inflammation, and swelling, by delivering gentle, non-invasive oscillations up to 8cm deep into the patient’s tissue in the affected area. The device has 3 key adjustable features: Output Frequency, Output Voltage, and Output Modulation.

  1. Adjustable Output Frequency Range (5-300 Hz): The output frequency range refers to the number of oscillations per second that the device can produce. A wider range allows for greater versatility in treatment, as different conditions may respond better to specific frequencies. Lower frequencies (5-50 Hz) are generally used for relaxation, reducing muscle spasms, enhanced lymphatic drainage, and promoting blood flow. Medium frequencies (50-150 Hz) can help with mobility, muscle strengthening and re-education, and movement of biological liquids and waste. Higher frequencies (150-300 Hz) may be more effective in pain management and the treatment of acute injuries, dissolving hardened tissue (including scars), reducing high muscle tone, and activating drainage pathways.(Primary competitor option adjustable up to only 250 Hz)

  2. Adjustable Output Voltage (0-900V): Output voltage is the intensity of the electrical signal produced by the device. By adjusting the voltage, you can control the strength of the oscillations and tailor the treatment to the patient’s needs and comfort level. Lower voltages are typically used for sensitive or superficial areas, while higher voltages may be more effective for deeper tissue or more stubborn conditions. It is essential to start at a low voltage and gradually increase it, ensuring the patient remains comfortable throughout the treatment.(Primary competitor option adjustable up to only 400V)

  3. Adjustable Output Modulation: In practical terms, the on/off ratio refers to the proportion of time that the device delivers oscillations (the “on” phase) compared to the time it’s inactive (the “off” phase) during a treatment cycle. By adjusting the on/off ratio, a practitioner can control the duty cycle and the intensity of the therapy, which can be helpful in targeting specific conditions or accommodating patient preferences, further enhancing the effectiveness and versatility of the THERADOT device.

Breakdown of Output Modulation Parameters:

On/Off Ratio Active Time (sec) Inactive Time (sec) Treatment Intensity Suitable Conditions & Uses
1/4 1 4 Lowest Intensity Highly sensitive patients or conditions requiring gentle treatment
(ex. Post-surgery recovery)
1/3 1 3 Low Intensity Mild to moderate sensitivity
(ex. Early-stage injury rehabilitation)
1/2 1 2 Balanced Intensity General treatment of various conditions
(ex. Acute pain relief or muscle relaxation)
2/3 2 3 Moderately High Intensity Treating stubborn issues or deeper tissues
(ex. Chronic pain)
3/4 3 4 High Intensity Challenging conditions; Faster recovery from intense physical activities
(ex. Long-term inflammation)
1/1 1 1 Continuous Treatment Wide range of conditions and patients
(ex. Balanced treatment for pain & muscle re-education)
2/1 2 1 Higher Intensity Chronic or deep-seated issues; More persistent muscle spasms
(ex. Sciatica)
3/1 3 1 Even higher Intensity More resistant conditions or patients who can tolerate stronger treatment
(ex. Severe tendonitis)
4/1 4 1 Highest Intensity Most challenging conditions or when maximum stimulation is desired
(ex. Severe chronic pain, advanced muscle strengthening)

Reviews

There are no reviews yet.

Be the first to review “Richmar THERADOT Deep Oscillation Therapy Device”

Your email address will not be published. Required fields are marked *