Description
Bard Bardex Lubricath Two-Way Specialty Latex Foley Catheter With 30cc Balloon Capacity provides smoother insertion and enhanced patient comfort through the hydrogel coatings unique ability to absorb fluid, thus creating a hydrophilic cushion between the catheter surface and the urethra. Hydrogel coating maintains its integrity throughout the course of use, resulting in less trauma upon removal.
Lubricath Two-Way Specialty Latex Foley Catheter Features:
- Short Round tip
- Two opposing drainage eyes
- Allows atraumatic insertion for enhanced patient comfort
More On Lubricath 2-Way Specialty Foley Catheter
Cautions:
- Do not aspirate urine through drainage funnel wall
- Some Foley catheters may contain Natural Rubber Latex which may cause allergic reactions
- Please check package
- Contains or Presence of Phthalates: Di(2-ethylhexyl)phthalate (DEHP) is a plasticizer used in some polyvinyl chloride medical devices
- DEHP has been shown to produce a range of adverse effects in experimental animals, notably liver toxicity, and testicular atrophy
- Although the toxic and carcinogenic effects of DEHP have been well established in experimental animals, the ability of this compound to produce adverse effects in humans is controversial
- There is no evidence that neonates, infants, pregnant and breast feeding women exposed to DEHP experience any related adverse effects. However, a lack of evidence of causation between DEHP-PVC and any disease or adverse effect does not mean that there are no risks
- With Temperature-Sensing Probes, in the presence of RF energy sources, local heating, temperature errors, and probe damage may occur
- In medical use, unplug the temperature-sensing catheter at the temperature monitor before activating electrosurgical or other types of direct coupled RF energy sources
- Do not stretch catheter. This will cause repositioning of the probe
- Do not use Stylet. This will cause stretching of the catheter
Warnings:
- On catheter, do not use ointments or lubricants having a petrolatum base. They will damage latex and may cause the balloon to burst
- After use, this product may be a potential biohazard. Handle and dispose of in accordance with the accepted medical practice and applicable local, state and federal laws and regulations
- Visually inspect the product for any imperfections or surface deterioration prior to use. Use Luer tip syringe to inflate with stated mL of sterile water OR for pre-filled products, remove the clip and squeeze reservoir to inflate with stated mL of sterile water
- Store catheters at room temperature away from direct exposure to light, preferably in the original box
Additional Information:
- This is a single-use device. Do not resterilize any portion of this device. Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient
- Aggressive traction, particularly in the presence of suturing is not recommended for 100% silicone catheters.
- Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient
- Do not exceed recommended balloon capacities
- Sterile unless the package is opened or damaged
- Catheters should be replaced in accordance with the CDC guideline, “Guideline for Prevention of Catheter-Associated Urinary Tract Infection.” At the onset or first signs of a urinary tract infection, catheter encrustation, or any other catheter-related adverse effect, the catheter should be replaced
Daily Maintenance:
- Do not use alcohol or prepackaged bathing systems, which could lead to early lifting. If showering/bathing, cover with plastic wrap or waterproof dressing
- Conduct skin assessment prior to application and repeat daily per facility protocol
- Use clinical judgment on the removal of the STATLOCK stabilization device if the patient experiences any fluid shifts that may interfere with skin integrity
- Sterile unless the package is opened or damaged






Reviews
There are no reviews yet.